Aerial view of a civic building with a folded bronze facade and standing seam roof

Engineered Roof Systems

Designed to perform. Built to endure.

We support architects and commercial builders with engineered roof systems that address condensation risk, structural performance, and compliance in demanding Australian climates.

Explore our systemsEnquire today
25+ YearsIndustry Experience
100+ ProjectsCommercial & Industrial
NCC CompliantHigh-Performance Roof Systems
About RoofLogic Australia

Decades of
roofing system
expertise

2 MarketsNew Zealand & Australia
3rd-Party TestedAcoustic & Structural Performance
End-to-EndEngineering & Technical Support
100+ ProjectsCommercial & Industrial
NCC CompliantHigh-Performance Roof Systems
25+ YearsIndustry Experience

Our mission is to deliver engineered roof systems that improve building performance through durability, thermal efficiency, and moisture control - without compromising compliance or constructability.

In conjunction with our approved roofing partners we aim to deliver complete, tested roofing systems — not just components. Every system is designed per project: structural, thermal and acoustic performance are assessed, and project-specific hygrothermal analysis confirms the specified assembly will manage condensation risk, mould growth and corrosion.

We support architects and builders with technical expertise from concept through to construction, ensuring long-term durability in demanding Australian conditions.

Our systemsGet in touch
Our work

Project portfolio

Explore completed projects showcasing Roof Logic roof systems in commercial and industrial environments across New Zealand — now supporting projects in Australia.

Request project details →
Ultratherm MSR · 2020

AS Colour

View larger ↗
Ultratherm MSR · 2025

The Mill – Sports Performance Hub

View larger ↗
Civic & community

Te Kahu o Waipuna, Marlborough

View larger ↗
Education

Khandallah School

View larger ↗
Multi unit residential

Madden Street

View larger ↗

RoofLogic roof systems

FiberthermX

Exploded diagram of the FiberthermX post and rail metal skin roof system

Insulated metal roof assembly utilising RL FiberthermX Post & Rail with Glasswool insulation to provide an economical high-performance roof system solution.

Ultratherm MSR

Exploded diagram of the Ultratherm MSR metal skin high-performance roof system

Insulated metal roof assembly with PIR or Stonewool insulation providing thermal, acoustic and structural performance to meet the precise requirements of your project.

Ultratherm Xtreme

Exploded diagram of the Ultratherm Xtreme membrane high-performance roof system

Insulated membrane roof assembly with PIR or Stonewool insulation providing thermal, acoustic and structural performance to meet the precise requirements of your project.

FiberthermX Recover

Exploded diagram of the FiberthermX Recover system installed over an existing metal roof

The FiberthermX Recover System refreshes existing metal roofing iron by utilising the Post & Rail System with Glasswool insulation.

Note: RoofLogic Australia does not supply the liner deck or external roof sheeting in Australia. These profiles are to be selected and supplied by the roofing contractor or project team and are subject to RoofLogic review for compatibility with our roof systems.

Ultratherm MSR Recover

Exploded diagram of the Ultratherm MSR Recover system installed over an existing metal roof

The Ultratherm MSR Recover System establishes a high-performance roof system solution by constructing it over existing metal roofing iron.

Ultratherm Xtreme Recover

Exploded diagram of the Ultratherm Xtreme Recover system installed over an existing substrate

The Ultratherm Xtreme Recover System enhances weathertightness and extends durability by applying a membrane system over existing substrates.

Why high-performance roof systems

High-performance roof system vs
traditional cold roof

Insulation above the LinerDeck, a vapour control layer at the correct point in the build-up, and a continuous thermal barrier — the difference shows up in energy use, condensation risk and lifecycle cost.

RecommendedRoofLogic roof system

Energy efficiency

Prevents heat loss through the roof: lower heating costs in winter, lower cooling costs in summer, reduced energy consumption overall.

Condensation controlled

Insulation above the LinerDeck keeps the structure warm, and a vapour control layer at the correct point ensures internal warm moist air never reaches its dew point.

Continuous thermal barrier

External insulation creates a continuous barrier, minimising thermal bridging and holding a more consistent internal temperature.

Lifecycle cost

At end of life the TopDeck can be removed and replaced without disrupting the rest of the system — the building stays occupied, with no tenting or evacuation.

Programme

Early close-in: the LinerDeck goes down first and protects the interior, with programme and health-and-safety benefits. Once it is down, the entire roof is trafficable.

Traditional cold roof

Heat loss through the roof

Discontinuous, poorly performing insulation layers leave a direct path for heat to flow through the assembly.

Vapour drive uncontrolled

Moisture-laden internal air passes through the roof/ceiling assembly, especially through porous materials like ceiling tiles.

Dew point inside the build-up

Moisture accumulates within wraps and insulation over time: reduced thermal performance, mould growth and corrosion risk.

Exacerbated thermal bridging

Structure penetrates the insulation line, bypassing it entirely and driving temperature fluctuation.

Disruptive replacement

Re-roofing typically means tenting, disposal of old materials and relocation of occupants.

Technical Specifier Guide · 2026 Edition

Warm Roof vs Cold Roof Systems in Australia: NCC Section J & Hygrothermal Condensation Guide

Compare net vs nominal R-values under AS/NZS 4859.2 thermal bridging rules, Climate Zone 1–8 vapour drive physics, WUFI condensation modelling, and whole-of-life cost benchmarks.

Read technical guide →
How we work

The path to system performance

From concept to construction, Roof Logic provides engineered system guidance, technical documentation, and project-specific support to ensure long-term roof performance.

  1. Te Pae Christchurch Convention Centre with curved metal roof and glass facade
    Step 01

    Project Review & System Selection

    We review your project scope, environmental conditions, compliance requirements, and performance targets to determine the most suitable roof system.

  2. Rydges Wellington Airport hotel with flat membrane roof overlooking the coastline
    Step 02

    Engineering & Specification

    Our team provides structural input, condensation risk assessment, thermal performance analysis, and detailed construction documentation tailored to Australian conditions.

  3. RoofLogic Helios bracket fixed to a trough profile roof
    Step 03

    Construction Support

    We support builders and contractors with system clarification, detailing assistance, and technical advice to ensure correct installation and long-term performance.

Get in touch

Enquire today

Call us on1300 266 316
Address

2190 Gold Coast Highway, Miami, Gold Coast, QLD, 4220.

PO Box 185, Miami, QLD, 4220

Frequently asked questions

Commercial warm roof engineering FAQs

Key technical answers for Australian architects, hydraulic consultants, structural engineers, and commercial builders.

What is a warm roof system?

A warm roof (externally insulated roof assembly) places continuous thermal insulation and a dedicated Vapour Control Layer (VCL) above the structural roof deck (LinerDeck or BaseDeck). This keeps the structural deck and interior air above the dew point, eliminates purlin thermal bridging, reduces HVAC energy loads, and mitigates interstitial condensation risk across Australian climate zones.

What roof systems does RoofLogic Australia offer?

RoofLogic Australia engineers four core system families: FiberthermX (non-combustible aluminium post & rail metal skin system with Glass Wool insulation), Ultratherm MSR (insulated metal skin roof system with PIR or Stonewool for complex geometries), Ultratherm Xtreme (single-ply Fibertite KEE or Derbigum membrane warm roof system for low-pitch applications), and Recover Systems (engineered non-intrusive overlays over existing commercial roofs), plus bespoke assemblies.

Are RoofLogic systems compliant with NCC 2022 Section J and Section F8?

Yes. All RoofLogic roof and façade assemblies are project-engineered for compliance with the National Construction Code (NCC) Volume One, including Section J (J4D3 thermal bridging and total system R-value calculations to AS/NZS 4859.2), Section F8 / F6 condensation management via transient WUFI hygrothermal modelling (ASHRAE 160), and AS/NZS 1170.2 wind load testing.

What areas does RoofLogic Australia service?

RoofLogic Australia services commercial, civic, educational, healthcare, retail, and industrial projects nationwide across all 8 Australian climate zones (QLD, NSW, VIC, WA, SA, TAS, ACT, and NT), supported from our head office at 2190 Gold Coast Highway, Miami, QLD 4220.

How do I request project specifications or hygrothermal analysis from RoofLogic Australia?

Call 1300 266 316, email info@rooflogicaustralia.com.au, or submit your project details via our online contact form. Our engineering team provides preliminary system selection, thermal/acoustic ratings, CAD/Revit construction details, and project-specific hygrothermal condensation analysis within 24–48 hours.